EasyManua.ls Logo

Alcatel-Lucent 5620 - Page 72

Alcatel-Lucent 5620
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 — Troubleshooting using network alarms
3-30 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: PrimaryDatabaseWasDown
Type: databaseAlarm (29)
Probable cause: primaryDatabaseWasDown
(193)
Severity: Warning
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): No
The alarm is raised when the primary
database returns to service after
being unavailable for at least one
poll.
Name: RealignmentOfDatabase
Type: configurationAlarm (11)
Probable cause: databaseRealignment (455)
Severity: Warning
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): No
The alarm is raised when the primary
5620 SAM main server realigns itself
with the preferred database by
performing a database switchover to
connect to the primary database.
Name: RealignmentOfDatabaseFailed
Type: configurationAlarm (11)
Probable cause:
databaseRealignmentFailed (456)
Severity: Critical
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): No
The alarm is raised when a database
switchover to realign the primary
main server and primary database
fails. The primary main server is not
connected to the preferred
database.
Name: ReinstantiateStandbyDatabase
Type: configurationAlarm (11)
Probable cause:
reinstantiateStandbyDatabase (191)
Severity: Warning
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): No
The alarm is raised when a standby
database reinstantiation occurs.
Name: ReinstantiateStandbyDatabaseFailed
Type: configurationAlarm (11)
Probable cause:
reinstantiateStandbyDatabaseFailed (192)
Severity: Critical
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): No
The alarm is raised when a standby
database reinstantiation fails.
Name: RowThresholdConstraintViolated
Type: configurationAlarm (11)
Probable cause:
partialConstraintEnforcement (218)
Severity: Major
Object Type (class):
SizeConstraintPolicy
Domain: db
Implicitly cleared (self-clearing): Yes
The alarm is raised when the number
of records in a database table
exceeds the number specified in a
size constraint policy.
Name: StagingDiskSpaceBelowThreshold
Type: databaseAlarm (29)
Probable cause: diskSpaceIssue (153)
Severity: Major
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): Yes
The alarm is raised when the primary
or standalone database staging disk
space threshold specified in the
nms-server.xml file is reached.
Name:
StandbyDataFileDiskSpaceBelowThreshold
Type: databaseAlarm (29)
Probable cause: diskSpaceIssue (153)
Severity: Critical
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): Yes
The alarm is raised when the standby
data file disk space threshold
specified in the nms-server.xml file
is reached.
Name:
StandbyInstallDirectoryDiskSpaceBelowThre
shold
Type: databaseAlarm (29)
Probable cause: diskSpaceIssue (153)
Severity: Major
Object Type (class):
DatabaseManager
Domain: db
Implicitly cleared (self-clearing): Yes
The alarm is raised when the standby
database installation disk space
threshold specified in the
nms-server.xml file is reached.
Alarm Attributes Additional information
(4 of 5)
Aug 2010
AAAD
8.0 R4

Table of Contents