3 — Troubleshooting using network alarms
3-44 Alcatel-Lucent 5620 Service Aware Manager, Release
Troubleshooting Guide 3HE 05723 TQZZA Edition 01
Name: SecondaryPathLimitReached
Type: resourceAlarm (28)
Probable cause: resourceLimitReached
(131)
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
secondary path bandwidth limit is
reached.
Name: SGLimitExceeded
Type: resourceAlarm (28)
Probable cause:
pimSnpgSGGroupMaxSupportedLimitExceed
ed (350)
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the number
of PIM snooping source group records
on a card exceeds the maximum.
Name: ShelfCPUAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfCPUUtilizationCrossedAboveThreshold
(474)
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when shelf CPU
usage exceeds the threshold value.
Name: ShelfMemoryAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfMemoryUtilizationCrossedAboveThresh
old (475)
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when shelf
memory usage exceeds the threshold
value.
Name: ShelfRxAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfRxUtilizationCrossedAboveThreshold
(476)
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when shelf Rx
exceeds the threshold value.
Name: ShelfRxTxAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfRxTxUtilizationCrossedAboveThreshold
(477)
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when shelf Tx
exceeds the threshold value.
Name: ShelfTemperatureAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfTemperatureUtilizationCrossedAboveT
hreshold (478)
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when shelf
temperature exceeds the threshold
value.
Name: SoftwareFailureAlarm
Type: softwareAlarm (19)
Probable cause: loadFailed (124)
Severity: Critical
Object Type (class): ReplaceableUnit
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the CPM
fails to load the software from the
specified location. The alarm
information includes the software
location.
Name: SSHServerPreserveKeyFailure
Type: softwareAlarm (19)
Probable cause: preserveKeyFailure (302)
Severity: Critical
Object Type (class): FlashMemory
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the CPM
fails to save the SSH server host key
on the persistent drive.
Name: SWIncompatibility
Type: configurationAlarm (11)
Probable cause:
elementNotCompatibleWithExistingStack
(357)
Severity: Major
Object Type (class):
StackConfiguration
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a slot is not
compatible with the current stack.
The slot subsequently enters
pass-through mode.
Alarm Attributes Additional information