3 — Troubleshooting using network alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 3-53
3HE 05723 TQZZA Edition 01 Troubleshooting Guide
Table 3-25 Domain: isa
Name: IPSecTunnelBfdConnectionDown
Type: serviceAlarm (16)
Probable cause: bfdSessionDown (346)
Severity: Minor
Object Type (class): IPSecTunnelBfd
Domain: ipsec
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
Operational State of a BFD session is
Not Connected.
Name:
IPSecTunnelBfdConnectionPeerDetectsDow
n
Type: serviceAlarm (16)
Probable cause:
bfdSessionConnectionPeerDetectsDown
(594)
Severity: Minor
Object Type (class): IPSecTunnelBfd
Domain: ipsec
Implicitly cleared (self-clearing): Yes
The alarm is raised when a BFD peer
detects a connection timeout.
Name: IPSecTunnelDown
Type: serviceAlarm (16)
Probable cause: tunnelDown (23)
Severity: Major
Object Type (class): IPSecTunnel
Domain: ipsec
Implicitly cleared (self-clearing): Yes
The alarm is raised when the IPsec
tunnel Operational State changes to
Down and the Administrative State is
Up.
Alarm Attributes Additional information
Name: IsaAaGrpCapCostThres
Type: equipmentAlarm (3)
Probable cause: IsaAaGrpCapCostThres
(595)
Severity: Warning
Object Type (class): AaGroupMember
Domain: isa
Implicitly cleared (self-clearing): No
The alarm is raised when the
capacity cost for an MDA in an ISA-AA
group reaches the configured
threshold.
Name: IsaAaGrpDown
Type: equipmentAlarm (3)
Probable cause: IsaAaGrpDown (482)
Severity: Major
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ISA-AA
group Operational State is Down, and
the Administrative State is Up.
Name: IsaAaGrpFailure
Type: equipmentAlarm (3)
Probable cause: isaAaGrpFailure (434)
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
The alarm is raised when an ISA-AA
Group has no configured primary
MDA or the number of active MDAs is
not equal to the number of
configured primary MDAs.
Name: IsaAaGrpFlowFull
Type: equipmentAlarm (3)
Probable cause: isaAaGrpFlowFull (436)
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
The alarm is raised when an ISA-AA
group uses a greater number of flow
records than the value specified by
tmnxBsxFlowFullHighWatermark.
Name: IsaAaGrpNonRedundant
Type: equipmentAlarm (3)
Probable cause: isaAaGrpNonRedundant
(435)
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
The alarm is raised when an ISA-AA
Group has a configured backup MDA
but there is no standby MDA
available.
Name: IsaAaGrpSwitchover
Type: equipmentAlarm (3)
Probable cause: isaAaGrpSwitchover (437)
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
The alarm is raised when an ISA-AA
group experiences an activity switch
from one ISA-AA to another.
(1 of 2)
Alarm Attributes Additional information
(2 of 2)
Aug 2010
AAAD
8.0 R4

Table of Contents