OpenFlow Command Reference
682 Router Configuration Guide
Default shutdown
flowtable
Syntax [no] flowtable of-table-id
Context config>open-flow>of-switch
Description This command configures the flow table parameters for this OpenFlow switch instance.
The no form of this command restores flow table configuration default settings.
Default no flowtable
Parameters of-table-id — Specifies an identifier of the OpenFlow table, a string up to 256 characters.
max-size
Syntax max-size size
no max-size
Context config>open-flow>of-switch>flowtable
Description This command configures the size for the specified flow table. The OpenFlow switch instance must be
shutdown to modify this parameter.
The no form of this command restores the default size.
Default no max-size
Parameters size — Specifies the maximum size limit for the flow table. The size limit is a total for both IPv4
and IPv6.
Values 1 to 262144
Default 1000
no-match-action
Syntax no-match-action {drop | fall-through | packet-in}
no no-match-action
Context config>open-flow>of-switch>flowtable
Description This command configures the action for the flow table when a packet does not match any entry for the
controller.
The no form of this command restores the default action.