Environmental and electrical characteristics
102 MPR-e
MPR-E: Maximum allowed cable lengths for MPT Power
Unit
MPR-A: Maximum allowed cable lengths for MPT Power
Unit
Start up temperature from low
temperature
-40° C
Humidity
(Guaranteed)
0 to 95%
Table 25: MPT Power Unit general characteristics
Table 26: Maximum allowed cable lengths for MPT Power Unit (MPR-E)
Cable type Coaxial cable
1AC001100022
Power only, Data
optical cable
Coaxial cable
1AC041350001
Power only, data
optical cable
Configuration Required power Maximum length Maximum length
MPT-HC V2 40 W 510 m 220 m
MPT-HC V2 with XPIC 48 W 440 m 190 m
Constraint 1 Maximum current in the Ethernet transformer < 1.8 A
Maximum current limit for the Power Unit: 1.8 A
Constraint 2 Minimum MPT-HC PSU input voltage > 28 V
Constraint 3 Data traffic only with optical cable
Table 27: Maximum allowed cable lengths for MPT Power Unit (MPR-A)
Cable type Coaxial cable 1AB350440001
Power only, data on optical cable
Configuration Required power Maximum length
MPT-HC V2 40 W 300 m