Product information and planning
MPR-e 103
General characteristics (MPT Extended Power Unit)
MPT-HC V2 with XPIC 48 W 300 m
Constraint 1 Maximum current in the Ethernet transformer < 1.8 A
Maximum current limit for the Power Unit: 1.8 A
Constraint 2 Minimum MPT-HC PSU input voltage > 28 V
Constraint 3 Data traffic only with optical cable
Table 27: Maximum allowed cable lengths for MPT Power Unit (MPR-A)
Table 28: MPT Extended Power Unit general characteristics
Standards Compliance (Power Extractor)
EMC EN 301 489-1, GR-1089 Class A
Storage ETS 300 019, Class 1.2, GR-3108
Transportation ETS 300 019 1-2, Class 2.3, GR-3108-CORE
Safety EN 60950, UL-60950
Environmental
Operating Temperature
(Guaranteed)
-40° to +65° C
Start up temperature from low
temperature
-40° C
Humidity
(Guaranteed)
0 to 95%