EasyManua.ls Logo

Alcatel-Lucent 9558HC - MCT Tool Bar; Figure 73 Tool Bar

Alcatel-Lucent 9558HC
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MCT tool bar
180 MPR-e
In a dedicated box, the MCT Launcher reports the Name, chassis type and location as per the
configuration performed in the 7705 SAR CLI.
The MCT Launcher reports the complete list of MPR-e configured in the 7705 SAR CLI,
reflecting their operative status. In a table format, the radio screen shows all MPR-e
information inherited according to the mw-link object (configured in CLI) they belong to.
Information for MPR-e units that are operative up appears in black in the list. Information for
MPR-e units that are operative down appear in grey.
The first column of the table reports the status of the MCT session for that specific MPR-e.
When a green triangle appears, no MCT sessions have been started by the MCT Launcher.
Single click on the green triangle or double click on the specific MPR-e line to start an MCT
session. When an MCT session is already opened for an MPR-e, the first column shows a red
square. Single click on the red square or double click on a specific MPR-e line to close the
MCT session.
When MCT Launcher is closed from either the tool bar or title bar button, all MCT sessions
started by the Launcher will close.
MCT tool bar
Figure 73: Tool bar
The MCT tool bar has 4 buttons:
Exit: to quit the application
Connect to NE: to establish the connection to the NE
Disconnect: to disconnect from the NE
Export NE Information: to export the NE configuration and current alarms to a text
file. Only the information related to the MPR-e is reported.
Note: The 7705 SAR supports up to six MCT sessions started by a single MCT Launcher
session.

Table of Contents

Related product manuals