Product information and planning
MPR-e 89
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
General with MPT-MC (MPR-E)
Operating Frequency Range 6 - 38 GHz
Max. Ethernet throughput 349 Mbps
Bandwidth up to 56 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Radio Path Protection Options 
Non Protected, 1+0
Standards Compliance 
EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B
Stationary use ETS 300 019, Class 4.1
Storage ETS 300 019, Class 1.2
Transportation ETS 300 019, Class 2.3
Safety IEC 60950-1/EN 60950-1
Radio Frequency EN 302 217 Classes 2, 4 & E5
Water Ingress IEC 60529 (IPX6)
Table 12: General characteristics (MPT-HC V2/MPT-MC/MPT-XP (MPR-E)/9558HC (MPR-A))
Table 13: Environmental characteristics (MPT-HC V2/MPT-MC/MPT-XP/9558HC)
Environmental 
Operating Temperature
(Guaranteed)
-33° to +55°C
Startup temperature from 
low temperature 
-40°C
Humidity
(Guaranteed)
0 to 100%
Management