Product information and planning
MPR-e 151
Figure 51: MPT extended power unit
The MPT Power Unit has 9 connectors:
Battery A/B (A & B power from office power)
MPT1/2 IDU Data (Data from MSS-1c or Ethernet generic device)
MPT1/2 DC + ODU Data (PFoE to MPT)
MPT1/2 DC (Power Supply to MPT)
Alarms (Alarm status)
LEDs
Two LEDs indicate the presence of DC voltage on each power input.
Two LEDs indicate the presence of DC voltage on each MPT power output.
Radio transmission features with MPT-HC V2/MPT-MC/
MPT-XP/9558HC
Frequency agility
The Frequency Agility feature gives the operator the ability to set the frequency of a single
Transceiver within a chosen sub-band to select the RF working channel via MCT. This
provides benefits for spare parts, order processing and frequency co-ordination.
9500 MPR
MPT1
DC
DC Voltage
DC+ODU Data
MPT Extended Power Unit
MPT2
DC
DC Voltage
DC+ODU Data
Alarms
Battery A
+ VDC -
Battery B
+ VDC -
VDC Normal +24 or -48V
VDC Range -/+19.2 to +57.6V
MPT1 Batt.A
MPT2 Batt.B
DC Voltage