Product information and planning
MPR-e 99
Table 22: MPT-XP power system: power requirements
Cable type Cable Length
Ethernet UTP 5E
1AC016760006
0 m ≤ 20 m 20 - 60m 60 - 100 m
Coaxial Cable
1AC001100022
0 m ≤ 56 m 56 - 168 m 168 - 280 m
Coaxial Cable
1AC041350001
0 m ≤ 25 m 25 - 75 m 75 - 125 m
Number
MPT
ODU
Input Voltage
for Extended
Power Unit
24
(Vdc)
48
(Vdc)
24
(Vdc)
48
(Vdc)
24
(Vdc)
48
(Vdc)
24
(Vdc)
48
(Vdc)
1 MPT MPT-XP + XPIC 81.0W 81.0W 81.0W 81.0W 81.0W 81.0W 81.0W 81.0W
Cable Losses 0.0W 0.0W 2.0W 2.0W 6.6W 6.6W 12.7W 12.7W
Extended Power
Unit
11.0W 15.4W 11.3W 15.8W 12.0W 16.7W 12.8W 17.8W
Total power
consumption
92.0W 96.4W 94.3W 98.8W 99.6W 104.3
W
106.5
W
111.5
W
2 MPT MPT-XP + XPIC 162W 162W 162W 162W 162W 162W 162W 162W
Cable Losses 0.0W 0.0W 4.0W 4.0W 13.3W 13.3W 25.4W 25.4W
Extended Power
Unit
22.1W 30.9W 22.6W 31.6W 23.9W 33.4W 25.6W 35.7W
Total power
consumption
184.1
W
192.9
W
188.6
W
197.6
W
199.2
W
208.7
W
213.0
W
223.1
W