Navigator area
210 MPR-e
Figure 104: Electrical 1 Gb/s active configuration with Internal Oscillator
Radio
1. Telecommunications standard
Select the ETSI or ANSI market.
2. Modulation
The operation mode can be with Fixed Modulation (FCM) or with the Adaptive 
Modulation (ACM).
→ Operation with Fixed Modulation (FCM) (Figure 106 and Figure 107)
-In the Coding Modulation Type field, select “Fixed (FCM)”.
-In the Channel Spacing field, select the suitable channel spacing to be used.:
MPR-E: up to 56 MHz for MPT-HC V2, MPT-MC, and MPT-XP
MPR-A: up to 50 MHz for MPT-HC V2, MPT-XP, and 9558HC
- Select the Modem Profile Option: Current Mask Standard Profile or New 
Mask Standard Profile
MPR-E: Current mask standard profile or New mask standard profile
MPR-A: Choose Standard Profile