E.4 Disabling the DHCP Client
In certain circumstances, it is convenient to partly disable the DHCP client. This way, the device
still gets its IP address from the DHCP server, however, additional settings possibly supplied by
the DHCP server are ignored. This is especially useful if in a given setup, some devices are to be
configured differently but the majority is still configured by DHCP.
Dialtone
type
Byte (8bit) No 210 The type of dialtone to
generate locally
Enter the numeric
dialtone type (0 -
EUROPE-PBX, 1 -
EUROPE-PUBLIC, 2 -
US, 3 - UK, 4 - ITALY-
PUBLIC, 5 - CZECH-
PBX, 6 - CZECH-
PUBLIC, 7 - SWEDEN,
8 - FRANCE, 9 -
SWISS, 10 - ITALY-
PBX, 11 - BELGIUM,
12 - NETHERLANDS,
13 - NORWAY, 14 -
DENMARK, 15 -
GERMANY, 16 -
SPAIN, 17 - FINLAND,
18 - AUSTRIA, 19 -
IRELAND, 20 -
AUSTRALIA, 21 -
NEWZEALAND, 22 -
MALAYSIA, 23 -
TURKEY, 24 -
RUSSIA, 25 - SOUTH
AFRICA, 26 - BRAZIL
)
Faststart Byte (8bit) No 211 Disable/Enable the
H245 faststart
procedure
To disable enter 0,
otherwise enter 1 into
the 8bit edit field
H245-
Tunnelling
Byte (8bit) No 212 Disable/Enable H245
tunneling
To disable enter 0,
otherwise enter 1 into
the 8bit edit field
Update
URL
String No 215 URL to retrieve update
commands from. This
is identical to the /url
option parameter of the
UP1 module
Complete URL as in
http://192.168.0.10/
file.txt. No symbolic
host names are
supported
Update Poll
Interval
Word (16bit) No 216 Standard poll interval
in minutes. This is
identical to the /poll
option parameter of the
UP1 module
Interval in minutes