Diagnostics and Troubleshooting
313
De te cte d Fault
Nam e Probable cause Rem edy
tnF
[Auto
-
tuning]
Special
motor
or
motor
w hose
power
is not suitable for the drive.
Motor not connected to the drive.
Motor not stopped
Check that the motor/drive are
compatible.
Check that the motor is present during auto-tuning.
If an output contactor is being used, close it during auto-tuning.
Check that the motor is stopped during tune operation.
ULF
[Proc. unde rload Flt]
Process underload.
Check and remove the cause of the underload.
Check the parameters of the
[PROC E S S
UNDE R L O A D]
(
Uld
-
)
function,
page
270.