Shut down the Börger machine and downstream and upstream
system components as described in
Ä
Chapter 5.4 “Down-
times” on page 100.
Secure the Börger machine against unauthorized or uncon-
trolled reactivation as described in
Ä
Chapter 2.7 “Securing the
machine against restart” on page 26
To the extent necessary, amply secure the surrounding area
when performing maintenance. Cordon off the working area
with a red and white safety chain and a warning sign.
Relieve the pressure in the Börger machine according to
Ä
Chapter 6.1.2 “Pressure relief” on page 114.
Clean the interior of the Börger machine as described in
Ä
Chapter 6.1.3 “Internal cleaning” on page 116.
1. Release the pressure from the clamping unit.
2. Remove the compressed-air tube (2) of the compressed-air
container (1) from the elbow union (4).
3. Loosen the hexagon head screws (3) from the plate (5) for
the rotating union (6).
Remove the plate for the rotating union
4. Pull the plate (5) with the rotating union (6) out of the cover
(8) so that you can remove the unit from the compressed-air
tube (7.1).
5. Loosen the two hexagon socket head cap screws (9) at the
cover of the clamping unit (8) and lift off the cover (8).