4. Using data logger support software, launch the EZSetup Wizard.
l
LoggerNet users, from the Main category click Setup and select the View menu to
ensure you are in the EZ(Simplified) view, then click Add .
l
PC400 users, click Add Datalogger .
5. Click Next.
6. Select CR300 Series from the list, type a meaningful name for your data logger (for
example, a site identifier or project name), and click Next.
7. Select the Direct Connect connection type and click Next.
8. Select the communications port used to communicate with the RF407-series radio from the
COM Port list. It should be listed as RF407-Series (COMX).
TIP:
If the RF407-Series (COMX) is not in the list ensure your RF407 is connected to your
computer.
9. Accept the default value of 00 seconds in the COM Port Communication Delay - this box is
used to allow time for hardware devices to "wake up" and negotiate a communications link.
Click Next.
13. Radio communications option58