Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
8.3 Hold Function
With the Hold function enabled during setup of the indicator, the
function must be activated before it can be used.
Refer to section 4.14 Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Hold function.
NOTE: This function is not available when Legal-For-trade (LFt=yes)
has been selected in setup. In addition, only one of the functions Hold,
Count, Peak Hold, Checkweigher or Live Weight can be active at a time.
8.3.1 Activate Hold Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show Hold X, the prompt and status of
the Hold function.
4. If the setting displayed is acceptable, press the TARE key to save
it. Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
0 = Hold Function Not Active
5. Repeatedly press the TARE key to step through the remaining
function prompts until the indicator returns to the weight display.
8.3.2 Hold Function Operation
1. With the Hold function enabled and activated, momentarily press the
Fn/ key and the display will lock at its current weight reading.
2. Press the PRINT key to print the held reading.
3. Press the NET/GROSS, ZERO, TARE , or UNITS/ key to release
the hold and return to the weight display.