EasyManua.ls Logo

Cardinal 190 Series - Setup

Cardinal 190 Series
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 171
18.3 Setup
Enter SETUP and proceed to the Options Setup.
option
With option displayed, press the TARE key. The display will change
to show opt=. Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE key. The display will change to
no. Press the Fn/ key to toggle to yes and then press the TARE
key. The display will change to opt=. Proceed to the opt= parameter.
Otherwise, to skip the Options Setup, press the TARE key to advance
to the fUnC?. prompt.
oPt= (Option)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/▲ key to toggle to a new setting and then press the TARE key to
save it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, WiFi or USB Option Card
Installed
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
rAnGE=
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/▲ key to toggle to a new setting and then press the TARE key to
save it. Allowable values are:
0 = 4-20 ma
1 = 0-20 ma
2 = 0-24 ma
3 = 0-10 volts
4 = 0-5 volts
5 = -10 to +10 volts
6 = -5 to +5 volts

Table of Contents