Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 113
8.11 ASCII Commands
The Model 190 indicator will respond to ASCII commands when input to
the 190’s internal serial port, the 190-RS232 option card, the 190-IP option
card, and the 190-WiFi option card.
Note that in order for the indicator to respond to the ASCII commands
described below, the internal serial port and the option cards must be set
to “Weight On Demand” output format.
Request Displayed Weight Command (Scoreboard Format)
The wireless device sends:
<ENQ> (hex 05)
The 190 will respond with weight in Cardinal Scoreboard format:
<S><XXXXXX><d>_<UU>_<m>_<cc>_<CR>
where:
<S>
=
sign
-” = negative
space = positive
<XXXXXX>
=
weight (six digits)
<d>
=
decimal point (embedded in weight, if enabled
in setup)
_
=
space
<UU>
=
units of measure
(“LB”, “OZ”, “KG”, or “G ”)
<m>
=
mode
G = gross
N = net
<cc>
=
weight status
OC = over capacity
CZ = center of zero
MO = unstable
EE = weight is not being displayed
“ ” = none of the above
<CR>
=
carriage return (hex 0D)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 190 Series and is the answer not in the manual?

Cardinal 190 Series Specifications

General IconGeneral
Touch TechnologyResistive
Display Size19 inches
Resolution1280 x 1024
Brightness250 nits
InterfaceUSB
Operating System CompatibilityWindows, Linux
Environmental RatingIP65
Active Area376.32 x 301.06 mm

Related product manuals