Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
4.14 Function Setup
fUnC
With FUnC displayed, press the TARE key. The display will change to
show Hold=. Proceed to the Hold = parameter.
FUnC?
With FUnC? displayed, press the TARE key. The display will change
to no. Press the Fn/ key to toggle to yes and then press the TARE
key. The display will change to HoLd=. Proceed to the HoLd=
parameter. Otherwise, to skip the Options Setup, press the TARE key
to advance to the Colors prompt.
IMPORTANT! The Hold, Count and Live Weight Features
should not be enabled if the Legal-For-Trade option
(LFt=yes) was selected during setup.
In addition, only one of the features Hold, Count, Peak Hold,
Checkweigher or Live Weight can be enabled at a time.
HoLd= (Hold Function)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it. Allowable values are:
Hold Function is Disabled
CoUnt= (Count Function)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it. Allowable values are:
Count Function is Enabled
Count Function is Disabled