Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 53
4.8 Serial Input/Output
Sio
With sio displayed, press the TARE key. The display will change to
baud=. Proceed to the baud= parameter.
Sio?
With sio? displayed, press the TARE key. The display will change
to no. Press the Fn/ key to toggle to yes and then press the
TARE key. The display will change to baud=. Proceed to the
baud= parameter. Otherwise, to skip Serial Input/Output setup, press
the TARE key to advance to the print?. prompt.
bAUd= (Serial Interface Baud Rate)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new baud rate for the serial ports and then press
the TARE key to save it. Allowable settings are:
12 = 1200 Baud
24 = 2400 Baud
48 = 4800 Baud
96 = 9600 Baud
19 = 19200k Baud
38 = 38400 Baud
76 = 76800 Baud
Prty= (Serial Interface Parity Setting)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it.
Allowable settings are:
0 = No Parity with 8 data bits
1 = Odd Parity with 7 data bits
2 = Even Parity with 7 data bits