14.2 Axle Weighing Mode
Setup
Axle weighing mode is enabled by setting the d oUt= parameter
to 5, setting the aUto= parameter to determine whether the scale
will be an automatic axle weigher or will function as a standard axle
weigher, setting the printer Port number to 1 or 2 and setting the
continuous output Cont on the selected port to NO.
d oUt= X,Y (Digital Output)
5 =
This setting enables the Axle Weighing Mode.
NOTE: The Model 190 cannot be upgraded to a Model 190A in
the field. It requires returning the 190 to the factory to perform
the upgrade.
When the d oUt= parameter is set to 5, the following prompts will be
enabled:
aUto= (Automatic Axle Weigher)
The aUto= (Automatic Axle Weigher) prompt determines whether
the scale will be an automatic axle weigher or will function as a
standard axle weigher, using the PRINT / Fn PRINT key functions
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
aUto=YES
aUto=no
Scale will be an automatic
axle weigher
Scale will be a standard
axle weigher

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 190 Series and is the answer not in the manual?

Cardinal 190 Series Specifications

General IconGeneral
Touch TechnologyResistive
Display Size19 inches
Resolution1280 x 1024
Brightness250 nits
InterfaceUSB
Operating System CompatibilityWindows, Linux
Environmental RatingIP65
Active Area376.32 x 301.06 mm

Related product manuals