Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
14.2 Axle Weighing Mode
Setup
Axle weighing mode is enabled by setting the d oUt= parameter
to 5, setting the aUto= parameter to determine whether the scale
will be an automatic axle weigher or will function as a standard axle
weigher, setting the printer Port number to 1 or 2 and setting the
continuous output Cont on the selected port to NO.
d oUt= X,Y (Digital Output)
This setting enables the Axle Weighing Mode.
NOTE: The Model 190 cannot be upgraded to a Model 190A in
the field. It requires returning the 190 to the factory to perform
the upgrade.
When the d oUt= parameter is set to 5, the following prompts will be
enabled:
aUto= (Automatic Axle Weigher)
The aUto= (Automatic Axle Weigher) prompt determines whether
the scale will be an automatic axle weigher or will function as a
standard axle weigher, using the PRINT / Fn PRINT key functions
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
Scale will be an automatic
axle weigher
Scale will be a standard
axle weigher