EasyManua.ls Logo

Cardinal 190 Series - Axle Weighing Mode

Cardinal 190 Series
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 140
14.2 Axle Weighing Mode
Setup
Axle weighing mode is enabled by setting the d oUt= parameter
to 5, setting the aUto= parameter to determine whether the scale
will be an automatic axle weigher or will function as a standard axle
weigher, setting the printer Port number to 1 or 2 and setting the
continuous output Cont on the selected port to NO.
d oUt= X,Y (Digital Output)
5 =
This setting enables the Axle Weighing Mode.
NOTE: The Model 190 cannot be upgraded to a Model 190A in
the field. It requires returning the 190 to the factory to perform
the upgrade.
When the d oUt= parameter is set to 5, the following prompts will be
enabled:
aUto= (Automatic Axle Weigher)
The aUto= (Automatic Axle Weigher) prompt determines whether
the scale will be an automatic axle weigher or will function as a
standard axle weigher, using the PRINT / Fn PRINT key functions
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
aUto=YES
aUto=no
Scale will be an automatic
axle weigher
Scale will be a standard
axle weigher

Table of Contents

Related product manuals