Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
4.13 Options Setup
option
With opt displayed, press the TARE key. The display will change to
show opt=. Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE key. The display will change to
no. Press the Fn/ key to toggle to yes and then press the TARE
key. The display will change to opt=. Proceed to the opt= parameter.
Otherwise, to skip the Options Setup, press the TARE key to advance
to the fUnC?. prompt.
opt= (Option)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new setting and then press the TARE key to
save it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, WiFi or USB Option Card Installed
(See Appendix C, D, E and G for details)
4 = Digital to Analog Converter Option Card Installed
(See Appendix F for details)
IMPORTANT! The settings for the following prompts, baUd=,
Prty=, and Cont2= are only applied when the opt= parameter
is set to 0 or 1.
bAUd= (Optional Serial Interface Baud Rate)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new baud rate for the serial ports and then press
the TARE key to save it. Allowable settings are: