Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
8.9 Accumulated Weight Function
When the accumulated weight function has been enabled during setup
of the indicator, the function must be activated before it can be used.
Refer to section 4.14 Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Hold function.
NOTE: If Legal-For-trade (LFt=yes) has been selected in setup, the
Gross weight must return to zero before the next weighing operation to
enable accumulation.
8.9.1 Activate Accumulated Weight Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show ACCU X, the prompt and status of
the Accumulated Weight function.
4. If the setting displayed is acceptable, press the TARE key to save
it. Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
1 = Accumulated Weight Function Active
0 = Accumulated Weight Function Not Active
5. Repeatedly press the TARE key to step through the remaining
function prompts until the indicator returns to the weight display.
8.9.2 Accumulated Weight Function Operation
During operation, the weight recorded when the PRINT key is pressed
will be added to the accumulator. This will be indicated by totAL
being displayed briefly after the PRINT key has been pressed.
1. To display the Accumulator, simultaneously press the UNITS/ and
TARE keys. If Legal-For-trade (LFt=yes) is on, the gross load
must be zero.
2. The Gross accumulator weight will be displayed as indicated by the
alternating G and A.
3. After a brief interval, the display will show the number of Gross weight
items accumulated, indicated by the alternating G and C.