Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
14.5 Wiring
OUT 1 RED light
OUT 2 GREEN light
The PWC outputs will always function if the indicator is set for d
oUt= 5 and AUto=YES. These outputs can be used, or the serial
output of the indicator can contain the light state information if
continuous data type = 2 (tYPE= 2, see below).
tyPE= (Continuous Output Format)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it. Allowable settings are:
0 = Continuous Output uses SMA format
1 = Continuous Output uses Cardinal Scoreboard format
2 = Continuous Output uses Cardinal SB500 with traffic
control format
NOTE: Refer to the CONT1= Continuous Output on Serial
Interface, tYPE= parameter section 4.8.1 and 4.8.2 for
description of output formats 0 and 1.
Cardinal SB500 with traffic control Continuous Output Format
If Cardinal SB500 with traffic control is selected, the data will be
transmitted in the following format:
%NDDDDDDDDDT<CR>
Where:
Panel number for a daisy chain configuration
Byte of data to display at respective location on the scoreboard
Control character for the traffic light. Valid characters for T are:
" "(space) = no lights on