Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
4.7 Set Gravity Constant
The Cardinal 190 Weight Indicator is equipped with an acceleration of gravity
function which means that it can be calibrated in one location and then adjusted
to match the acceleration of gravity at the location where it will used.
SEtgC
With sEtgC displayed, press the TARE key. The display will change to
CaLgC=. Proceed to the CaLgC= parameter.
SEtgC?
With sETgC? displayed, press the TARE key. The display will
change to no. Press the Fn/ key to toggle to yes and then press the
TARE key. The display will change to CaLgC=. Proceed to the
CaLgC= parameter. Otherwise, to skip the Set Gravity Constant setup,
press the TARE key to advance to the Sio?. prompt.
CALgC= (Calibrated Gravity Constant)
This is the acceleration of gravity value of the location where the scale
was calibrated. Set to 0 if calibrated at location of operation or if gravity
constants are not going to be used.
Press the TARE key to show the current setting. If the value
displayed is acceptable, press the TARE key to save it. Otherwise,
use the Fn/ and UNITS/ keys to enter a new value and press the
TARE key to save it
oPgC= (Operating Gravity Constant)
This is the acceleration of gravity value for the location where the scale
will be operated.
Press the TARE key to show the current setting. If the value
displayed is acceptable, press the TARE key to save it. Otherwise,
use the Fn/ and UNITS/ keys to enter a new value and press the
TARE key to save it. Consult the factory Tech Support for the
Acceleration of Gravity value for your location.