14.3 Standard Axle Weighing Operation
After placing the wheel load weighers on the ground in front of the steering
axle, the two weighers are connected together using the interconnection
cable assembly. One weigher (makes no difference which) is connected
to the indicator using the indicator interface cable. The interconnection
diagram is shown below:
Indicator Cable
Interface Cable
Wheel Load Wheel Load
Weigher Weigher
Power
1. Power the indicator on.
2. If the weight display is not 0, press the ZERO key.
3. Have the vehicle driven onto the axle load weighers until each wheel is
centered on the respective axle load weigher.
4. The axle weight will be displayed on the indicator.
5. When the display shows that the weight is stable, press the PRINT key
to record the weight.
6. Have the vehicle driven forward until the next set of wheels are
centered on the axle load weighers.
7. Press the PRINT key to record the weight.
8. Alternatively, to get the total weight of a group of axles, press the Fn/
key.
9. The display will show grP=.
10. Press the TARE/Enter key and the number 0 will be displayed.
11. Press the Fn/ key until the number of axles in the group is displayed.
12. Press the PRINT key to record the weight of the first axle.