Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
8.8 Live Weight Function
With the Live Weight function enabled during setup of the indicator, the
function must be activated before it can be used.
Refer to section 4.14 Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Hold function.
NOTE: This function is not available when Legal-For-trade (LFt=yes)
has been selected in setup. In addition, only one of the functions Hold,
Count, Peak Hold, Checkweigher or Live Weight can be active at a time.
8.8.1 Activate Live Weight Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show ACT X, the prompt and status of
the Live Weight function.
4. If the setting displayed is acceptable, press the TARE key to save
it. Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
1 = Live Weight Function Active
0 = Live Weight Function Not Active
5. Repeatedly press the TARE key to step through the remaining
function prompts until the indicator returns to the weight display.
8.8.2 Live Weight Function Operation
With the Live Weight function enabled and activated, make sure the
scale platform is empty, and then simultaneously press the
NET/GROSS and the UNITS/ key.
The Hold annunciator will flash.
Load the scale platform.
When a stable value has been reached, the Hold annunciator will be
on steadily and the display will lock.
Press the NET/GROSS key to return to the weight display.