Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
4.12 Key Lockout Feature
The Key Lockout Feature allows keys on the indicator to be disabled for
use by the operator “during normal operation”. During normal operation,
when the operator presses a locked key, the display will show LoCd for
about a 1/2 second and the key will be ignored.
NOTE: The Key Lockout Feature only disables keys for use
during normal operation, not setup and calibration.
LoCoUt
With LoCoUt displayed, press the TARE key. The display will change
to show 2ero=. Proceed to the 2ero= parameter.
LCoUt?
With LoCoUt? displayed, press the TARE key. The display will
change to no. Press the Fn/ key to toggle to yes and then press the
TARE key. The display will change to 2ero=. Proceed to the 2ero=
parameter. Otherwise, to skip the Key Lockout Feature setup, press the
TARE key to advance to the opt?. prompt.
2Ero= (ZERO Key)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new setting and then press the TARE key to
save it.
Key is Unlocked (Enabled)
tAre= (TARE Key)
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new setting and then press the TARE key to
save it.
Key is Unlocked (Enabled)