Request Displayed Weight Command (SMA Format)
The wireless device sends:
<LF>W<CR>
The 190 will respond with displayed weight in SMA format:
<LF><s><r><n><m><f><xxxxxxx.xxx><uuu><CR>
where:
<LF>
=
line feed (hex 0A)
<s>
=
scale status
Z = center of zero
O = over capacity
U = under capacity
E = zero error
T = tare error
e = weight is not being displayed
space = none of the above
NOTE: For the E or T error conditions,
<xxxxxxx.xxx> = ----------
<r>
=
range (always 1)
<n>
=
mode
G = gross
T = tare
N = net
<m>
=
motion status
M = unstable
space = stable
<f>
=
always a space
<xxxxxxx.xxx
>
=
weight (fixed at ten characters)
<uuu>
=
units of measure
(“lb ”, “oz ”, “kg ”, or “g ”)
<CR>
=
carriage return (hex 0D)