5-TRANSPORTOPERATIONS
4.Connectahandpumpwiththecapacitytoreachand
maintain2275kPa(330.0psi)22.7bar(329.2psi).
5.Operatethepumpuntilthecorrectpressureis
reached,andthebrakesarereleased.
6.Checkandmaintain2275kPa(330.0psi)22.7bar
(329.2psi)maximuminthebrakelinewhenmoving
themachine.Damagetothebrakesystemcanresult
ifthepressureisreduced.
7.Movethemachinefollowingsafetyguidelinesfor
movingadisabledmachine.
8.Disconnectthehandpump.
9.Removetheplug,andreconnectthelinestothe
brakesolenoid.
10.Removethevacuumpump,ifused.
11.Tightenthereliefvalveengagementscrewsbackin
carefully,andreplaceprotectivecapwithanewcap.
NOTICE:Theprotectivecappreventsdamageorinad-
vertentmovementoftheengagementscrew.
5-8