7-MAINTENANCE
Every500hours
Changeengineoilandlter
Changetheengineoilandlterwhenthehourmeterregisters500hours.Changetheengineoilandlterevery500
hoursthereafterormorefrequentlywhentheengineoperatingconditionsaresevere.
Prioroperation:
Keepallunauthorizedpersonnelclearofthearea.Parkthemachineonlevelground,inneutralwiththeparkingbrake
applied,andtheattachmentloweredtotheground,turnofftheengine,removethekey,andverifythatenginecom-
ponentshavecooledoravoidcontact.Makesurethatallresidualpressureisrelievedfromcircuitsbeforebeginning
maintenance.
Servicespecications
TypeofoilCASEAKCELAUNITEKNO.1™SBLCJ-4SAE
10W-40
Capacity(withlterchange)16.4l(17.3USqt)
Capacity(withoutlterchange)15.6l(16.5USqt)
1.Opentheleft-handfrontandright-handfrontaccess
doors.Securetheaccessdoorswiththedoorstruts
(1).
2.Removetheoildipstickandtheoilllcap.
NOTE:Oildrainsfasterwhentheoiliswarm(butnothot)
andtheoildipstickandoilllcapisremoved.
3.Useasuitablecontainertocollectthedrainedoil.
RAIL13DOZ0949AA1
4.Removetheboltsandtheengineoilaccessplateunder
theengine.Locatetheoildrainplug.
RAPH12DOZ0095AA2
NOTE:Ifthemachineissoequipped,usetheengineoilenvironmentaldrainlocatedinsideoftherightsideengine
accesshood.
7-56