7-MAINTENANCE
Every10hours
Engineoil
Theengineoillevelshouldbecheckedevery10hourshiftoreachday,whicheveroccursrst.
Prioroperation:
Keepallunauthorizedpersonnelclearofthearea.Parkthemachineonlevelground,inneutralwiththeparkingbrake
applied,andtheattachmentloweredtotheground,turnofftheengine,removethekey,andverifythatenginecom-
ponentshavecooledoravoidcontact.Makesurethatallresidualpressureisrelievedfromcircuitsbeforebeginning
maintenance.
Servicespecications
TypeofoilCASEAKCELAUNITEKNO.1™SBLCJ-4SAE
10W-40
Capacity(withlterchange)16.4l(17.3USqt)
Capacity(withoutlterchange)15.6l(16.5USqt)
Theengineoildipstick(1)andoilll(2)arelocatedon
theleftsideofthemachineinthefrontenginecompart-
ment.
RAPH12DOZ0069AA1
1.Removethedipsticktochecktheengineoillevel.
2.Wipethedipstickcleanandreinsert.Theoillevel
shouldregisteratthefullmark.
3.Addoil,ifnecessary.Donotoverllengineoil.
RAIL12DOZ0171AA2
NOTE:Thisprocedureisbestperformedatthebeginningoftheworkdaywiththeenginecoolandalloildrainedto
thepan.
7-31