7-MAINTENANCE
7.Cleanthecables.Coatthenewbatteryterminalswith
greaseoranti-suldespray.
8.Reconnectthepositivecableendstothepositiveter-
minals(3)rst,thenreconnectthenegativecableends
tothenegativeterminals(2).
9.T orquethebatteryterminalnuts(2)and(3)to21.5-
24.0N·m(15.9-17.7lbft).
RAIL12DOZ0174AA6
10.Installtheterminalprotectioncaps(1).
RAIL12DOZ0174AA7
11.TurnelectronicdisconnectswitchtotheONposition.
RAPH12DOZ0121AA8
7-117