DLP-G31 Install the FlexLayer Modules
This task installs the FlexLayer modules in the FlexLayer shelf. You can only
install two-channel FlexLayer modules.
Purpose
#2 Phillips Dynamometric screwdriver
FlexLayer modules
Tools/Equipment
NonePrerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Procedure
Step 1 Determine the FlexLayer modules that you want to install in the FlexLayer shelf. The FlexLayer shelf can
house up to four Add/Drop FlexLayer modules or four Y-cable splitter modules. The following table lists the
two-channel FlexLayer modules and part numbers.
Table 23: ONS 15xxx Two-Channel Add/Drop FlexLayer Module Hardware Part Numbers
DescriptionPart Number
ITU-100 GHz 2 Ch, FlexMod - 1530.33 and 1531.1215216-FLB-2-31.1=
ITU-100 GHz 2 Ch, FlexMod - 1531.90 and 1532.6815216-FLB-2-32.6=
ITU-100 GHz 2 Ch, FlexMod - 1534.25 and 1535.0415216-FLB-2-35.0=
ITU-100 GHz 2 Ch, FlexMod - 1535.82 and 1536.6115216-FLB-2-36.6=
ITU-100 GHz 2 Ch, FlexMod - 1538.19 and 1538.9815216-FLB-2-38.9=
ITU-100 GHz 2 Ch, FlexMod - 1539.77 and 1540.5615216-FLB-2-40.5=
ITU-100 GHz 2 Ch, FlexMod - 1542.14 and 1542.9415216-FLB-2-42.9=
ITU-100 GHz 2 Ch, FlexMod - 1543.73 and 1544.5315216-FLB-2-44.5=
ITU-100 GHz 2 Ch, FlexMod - 1546.12 and 1546.9215216-FLB-2-46.9=
ITU-100 GHz 2 Ch, FlexMod - 1547.72 and 1548.5115216-FLB-2-48.5=
ITU-100 GHz 2 Ch, FlexMod - 1550.12 and 1550.9215216-FLB-2-50.9=
ITU-100 GHz 2 Ch, FlexMod - 1551.72 and 1552.5215216-FLB-2-52.5=
ITU-100 GHz 2 Ch, FlexMod - 1554.13 and 1554.9415216-FLB-2-54.9=
ITU-100 GHz 2 Ch, FlexMod - 1555.75 and 1556.5515216-FLB-2-56.5=
Cisco ONS 15454 Hardware Installation Guide
128
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
DLP-G31 Install the FlexLayer Modules