Procedure
Step 1 Complete either DLP-G292 Install Timing Wires in ONS 15454 M2 - ANSI, on page 255 or DLP-G293 Install
Timing Wires in ONS 15454 M2 - ETSI, on page 257 if you are provisioning external timing.
Step 2 Complete DLP-G294 Install LAN Wires in ONS 15454 M2, on page 261 to create an external LAN connection.
You must connect a CAT-5 Ethernet cable to the LAN port on the TNC/TNCE/TSC/TSCE/TNCS-2/TNCS-2O
card to create an external LAN connection.
Stop. You have completed this procedure.
DLP-G292 Install Timing Wires in ONS 15454 M2 - ANSI
This task installs the timing wires in the DC-2 or AC-2 Power Module of ONS
15454 M2 (ANSI).
Purpose
100-ohm wire wrap cable, wire wrap toolTools/Equipment
NonePrerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Procedure
Step 1 Locate the timing BITS connectors in the DC-2 or AC-2 Power Module, as shown in the following two figures.
Cisco ONS 15454 Hardware Installation Guide
255
Installing the ONS 15454 M2 Shelf
DLP-G292 Install Timing Wires in ONS 15454 M2 - ANSI