Step 6 Enter the following interface commands:
Example:
(Router(config)# interface POS0
(Router(config)# no ip address
(Router(config)# no ip route-cache
(Router(config)# shutdown
(Router(config)# crc 32
(Router(config)# interface POS1
(Router(config)# no ip address
(Router(config)# no ip route-cache
(Router(config)# shutdown
(Router(config)# crc 32
(Router(config)# ip classless
(Router(config)# no ip http server
Stop. You have completed this procedure.
NTP-G307 Performthe ONS 15454ShelfInstallation Acceptance
Test
Use this procedure to perform a shelf installation acceptance test for the ONS
15454 ETSI or ONS 15454 ANSI.
Purpose
VoltmeterTools/Equipment
Applicable procedures in Installing the ONS 15454 M12 (ANSI and ETSI) Shelf,
on page 23
Prerequisite Procedures
RequiredRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Procedure
Step 1 If you installed an ONS 15454 ETSI shelf, complete the following table by verifying that each applicable
procedure was completed.
Table 24: ONS 15454 ETSI Shelf Installation Task Summary
CompletedDescription
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454 M6 Shelves,
on page 20
Cisco ONS 15454 Hardware Installation Guide
143
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
NTP-G307 Perform the ONS 15454 Shelf Installation Acceptance Test