DescriptionPart Number
ITU-100 GHz 2 Ch, FlexMod - 1558.17 and 1558.9815216-FLB-2-58.9=
ITU-100 GHz 2 Ch, FlexMod - 1559.79 and 1560.6115216-FLB-2-60.6=
Step 2 Insert the appropriate module into the FlexLayer shelf.
Step 3 Use a Phillips Dynamometric screwdriver to install the two accompanying screws.
The following figure shows the FlexLayer shelf and how the FlexLayer modules can be installed.
Figure 63: ONS 15xxx FlexLayer Shelf
Step 4 Repeat this task as necessary for each FlexLayer module you want to install.
Step 5 Return to your originating procedure (NTP).
DLP-G32 Install the Y-Cable Protection Modules in the FlexLayer Shelf
This task installs the Y-cable protection modules in the FlexLayer shelf.Purpose
#2 Phillips Dynamometric screwdriver
Y-cable module(s): Multi-Mode Y-Cable Protection FlexModule(s)
(15216-CS-MM-Y) or Single-Mode Y-Cable Protection FlexModule(s)
(15216-CS-SM-Y), as appropriate
Tools/Equipment
NonePrerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Cisco ONS 15454 Hardware Installation Guide
129
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
DLP-G32 Install the Y-Cable Protection Modules in the FlexLayer Shelf