DLP-G588 Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for
ETSI Rack Configuration
This task installs the bracket with air deflectors (front-to-top configuration) on
the ONS 15454 M2 shelf.
Purpose
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
Tools/Equipment
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves, on page 20
Prerequisite Procedures
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Use only the fastening hardware provided with the ONS 15454 M2 to prevent loosening, deterioration, and
electromechanical corrosion of the hardware and joined material.
Caution
The air deflectors can be installed only in the front position of the chassis.
Note
Procedure
Step 1 Place the right front air deflector flush against the right side of the chassis (see Diagram 1 of Figure 129:
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page 209).
Step 2 Align the screw holes on the right front air deflector with the screw holes on right side of the chassis.
Step 3 Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Step 4 Place the air deflector cover on the rear end of the chassis.
Step 5 Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m). See Diagram 2 of Figure 129:
Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack
Configuration, on page 209).
Step 6 Place the mounting bracket flush against the left side of the chassis (see Diagram 2 of Figure 129: Mounting
the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration,
on page 209).
Step 7 Align the screw holes on the mounting bracket with the screw holes on the left side of the chassis.
Step 8 Insert the screws and tighten them to a torque value of 11.5 in-lb (1.3 N-m).
Step 9 Place the mounting bracket flush against the right side of the chassis (see Diagram 2 of Figure 129: Mounting
the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration,
on page 209).
Cisco ONS 15454 Hardware Installation Guide
208
Installing the ONS 15454 M2 Shelf
DLP-G588 Mounting the Bracket with Air Deflectors (Front-to-Top) on the ONS 15454 M2 Shelf for ETSI Rack Configuration