INS_CNGE3FE8MS[POE][HO] Rev. 11.7.17 PAGE 313
INSTRUCTION MANUAL CNGE3FE8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Configuring MEP and ERPS on Switch 3
mep 1 down domain port flow 1 level 0 interface GigabitEthernet 1/1
mep 1 mep-id 5
mep 1 vid 3001
mep 1 peer-mep-id 1
mep 1 cc 0
mep 1 aps 0 raps
mep 2 down domain port flow 2 level 0 interface GigabitEthernet 1/2
mep 2 mep-id 6
mep 2 vid 3001
mep 2 peer-mep-id 4
mep 2 cc 0
mep 2 aps 0 raps
erps 1 major port0 interface GigabitEthernet 1/1 port1 interface GigabitEthernet 1/2
erps 1 mep port0 sf 1 aps 1 port1 sf 2 aps 2
erps 1 vlan 1
Note: To set the CCM rate to 100FPS or 300FPS, the peer MAC address must be known as shown
here, Or set it to lower rate first, until the peer MAC address is learned, and then change it
to a higher rate.
mep 1 peer-mep-id <peer mep id> mac <peer mac address>
mep 1 cc 0 fr300s
Finally, the ERPS status can be checked with the show erps command.