INS_CNGE3FE8MS[POE][HO] Rev. 11.7.17 PAGE 37
INSTRUCTION MANUAL CNGE3FE8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Security
Switch Security
Users
This page provides an overview of the current users. Currently the only way to login as another
user on the web server is to close and reopen the browser.
Object Description
User Name A string identifying the user name that this entry should belong to. The allowed string length is 1
to 31. The valid user name allows letters, numbers and underscores.
Password The password of the user. The allowed string length is 0 to 31. Any printable characters including
space are accepted.
Privilege Level The privilege level of the user. The allowed range is 1 to 15. If the privilege level value is 15, it can
access all groups, i.e. that is granted the fully control of the device. But others value need to refer
to each group privilege level. User’s privilege should be same or greater than the group privilege
level to have the access of that group. By default setting, most group privilege level 5 has the
read-only access and privilege level 10 has the read-write access. And the system maintenance
(software upload, factory defaults and etc.) need user privilege level 15. Generally, the privilege
level 15 can be used for an administrator account, privilege level 10 for a standard user account
and privilege level 5 for a guest account.
Add New User Click to add a new user.
Cancel Click to undo any changes made locally and return to the Users.
Apply Click to apply changes.
Reset Click to undo any changes made locally and revert to previously saved values.
Delete User Click to delete the currently selected user.