3033-009B Section 9: Flavor System
Concordia Xpress Technical Support Manual 9-11
2900-300B
8. Mix two packets of CLEANER #2 into the container of hot water.
Stir until cleaner is dissolved.
9. Place the flavor tube nozzles into the CLEANER #2 cleaning
solution.
10. Run the RUN SYRUP CLEAN process.
NOTE: Ensure all flavor tube nozzles remain completely
submerged during the cleaning cycle.
11. Once the cycle completes, place the flavor tube nozzles on a
clean towel, and then empty and rinse the container.
12. Refill the container with hot water as in step 2 above.
13. Place the flavor tube nozzles into the container with the hot
water.
14. Run the RUN SYRUP CLEAN process.
NOTE: Ensure all flavor tube nozzles remain completely
submerged during the cleaning cycle.
15. Once the cycle completes, place the flavor tube nozzles on a
clean towel, and then empty and rinse the container.
16. Run a milk clean cycle (see milk clean instructions).
17. Once the milk clean cycle is complete, wipe the product nozzle
with a clean cloth soaked in a sanitizer approved by your State
and Local Health Department regulations. Spraying the solution
onto and around the nozzle and then wiping it down with a
soaked clean cloth is quite effective.
18. Reconnect the flavor tube nozzles to the appropriate bag-in-box
flavors.
19. Prime the syrup system. See the Priming the Flavor Delivery
System topic on page 9-12 for instructions.