EasyManua.ls Logo

Concordia XPRESS - Cleaning Timers; Preventive Maintenance

Concordia XPRESS
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3033-011B Section 11: Cleaning and Maintenance
Concordia Xpress Technical Support Manual 11-3
2900-300B
Cleaning Timers
The milk system and brew group must be cleaned every 24 hours, or
after every 300 drinks, whichever comes first. If these cleaning
procedures are not completed within two hours of notification, the
machine will be disabled and will stop dispensing drinks until cleaning is
performed.
All timers start after the first drink is poured following a cleaning. For
example, if the machine is cleaned on Friday night, and it is idle Saturday
and Sunday, the timers are not started until the first drink is poured
Monday morning.
Preventive Maintenance
A Preventive Maintenance (PM) call must be performed periodically, in
order to service critical equipment functions and to minimize potential
future failure and reduce down time. Every 30,000 drinks, the message
REQUEST PM will be displayed on the message screen.
A PM kit (PN 5000-038), containing all the required replacement parts
and procedures, is available from Concordia Beverage Systems.
Navigate to MISCELLANEOUS > RESET PM to reset the PM counter.