Section 3: Electrical 3033-003B
3-18 Concordia Xpress Technical Support Manual
2900-300B
DC Power Supply Board LEDs
The LEDs on the power supply board indicate the presences of state DC
voltage compared to the expected DC voltage. The LED will illuminate if
there is a rise or drop in current.
Associated
Fuse on DC Board
GREEN
Lit during
normal
operation
CPU, ICs, Display, AC
Interface, DC Board, Hall
Effect Sensors
All Fans and Valves, Relays,
Main AC Relays/Contactor
All Valves & Fans, Relays,
Main AC Relays/Contactor
No Specific Component. This
supplies the 12Vdc
Transducer, Display, CPU
Analog Board, Steam Tank
Level Sensor
Transducer, Display, CPU
Analog Board, Steam Tank
Level Sensor
5 v vcc
Varying
Controlled
Current
CPU, Display, AC Interface,
DC Board, Hall-Effect
Sensors, Flowmeter
CPU, Display, and
Transducer