3033-015B Section 15: Troubleshooting
Concordia Xpress Technical Support Manual 15-45
2900-300B
Electrical System: Milk Pump Running
Continuously
Milk pump
continuously running
Power unit off, wait 15 seconds,
and power unit on. Press the
PROGRAM button twice and
note the part number of the
software version. Call
Concordia Beverage Systems
and verify software type.
1-800-778-0990
If software version is
updated for milk pump cutoff,
then a more current version
of the software will clear this
error.
Software
current?
No
Yes
Probable hardware
problem. Isolate
pump power.
Upgrade unit with
correct upgrade kit.
PN 2820-027
END PROCESS
See the Milk
Overpouring
troubleshooting
tree for further
assistance.