Product Reference Guide 73
Control Characters
Specifies how the scanner transmits ASCII control characters to the host.
Choices are:
• Disable Control Characters
• Enable transmission of control characters to host
• Send characters between 00H and 1FH according to a special function-key
mapping table. (This is used to send keys that are not in the normal ASCII
set; a unique set is provided for each available scancode set. Reference
Appendix E, Keyboard Function Key Mappings.)
START / END
PROGRAMMING bar codes
Disable Control Characters
DEFAULT
Enable Transmission of Control Characters
Enable Function Key Mapping