RS20i Installation and Operating Guide Page E-17
Appendix E. Remote Command API Document #: 9301H52900 Ver. 1.02
32. Identify
Get system identify information. Mostly used in discovery protocol.
Command: @IDENTIFY<cr>
Operation
Response: AP20<space>IP,
[info2],[info1],[screen]<cr>
Read
Parameters
AP20 General identifier for Datasat audio processor product. See
MODEL command to determine an RS20i model.
ip
IP address (useful after network broadcast command)
[Info2] User entered information, if entered in the RS20i configuration.
[
Info1] User entered information, if entered in the RS20i configuration.
[
Screen] User defined ID string, if entered in the RS20i configuration.
33. Model
Determines that the Datasat Audio processor is an RS20i.
Command: @MODEL<cr>
Operation
Response: MODEL<space>RS20i<cr>
Read
Parameters
RS20i
An RS20i returns this model string.
34. Authorization
Command: @AUTH<space>[Password]<cr>
Operation
Response:
AUTH<space>[SETUP|OP|SECERR]<cr>
Read
Give a password to allow usage of restricted commands. The authorization is required
for many commands if access to the RS20i has been configured with a Password. The
AUTH must be issued before issuing any password protected commands, and is valid
only for the duration of the TCP/IP connection.
Note: This application accepts only Latin alphanumeric characters.
There are two levels of password protection in the RS20i. Both levels are set in the
System > Access Control screen on the RS20i. The top password labeled NetCmd
Password will allow access to the RS20i for Operator level type commands. The bottom
password labeled Setup Password allows access to setup and configuration level
commands. The commands in this document only require the operator level password
(if set).
The AUTH may be used for either the Operator or Setup level password.
Parameters:
[Password] NetCmd or Setup level password. The RS20i compares this first
with setup level password and gives Setup Level authorization if it
matches. Otherwise, it compares it to the NetCmd password and
authorizes operator commands if it matches.
SETUP The RS20i returns this value when Setup Level authorization has
been granted.
OP The RS20i returns this value when NetCmd Level authorization
has been granted.