Troubleshooting
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
M m Alarm text Type Meaning ActionM m Alarm text Type Meaning Action
2 147 Hydraulic
pump - too
long time in
idle load
Deviation The measured pressure cannot
reach 34 bar when the pump loads
after parking the arm.
Check the pressure on the touch screen.
The pressure should vary between 29 and
34 bar during teat cleaning, attach and
disinfect (here we have arm movements). If
the error is repeated often, contact service.
Check the unloading valve.
2 147 Hydraulic
pump - too
long time in
idle load
Deviation The measured pressure cannot
reach 34 bar when the pump loads
after parking the arm.
Check the pressure on the touch screen.
The pressure should vary between 29 and
34 bar during teat cleaning, attach and
disinfect (here we have arm movements). If
the error is repeated often, contact service.
Check the unloading valve.
2 148 Hydraulic
pump - too
low pressure
in boost
mode
Deviation Cannot reach 40 bar in boost
mode (limit is 36 bar).
Check the hydraulic pressure on the touch
screen. Check the unloading valve. Call
service.
2 148 Hydraulic
pump - too
low pressure
in boost
mode
Deviation Cannot reach 40 bar in boost
mode (limit is 36 bar).
Check the hydraulic pressure on the touch
screen. Check the unloading valve. Call
service.
2 149 Hydraulic
pump - SW
internal error
Stop alarm Bug Should never occur. But if it does, restart
the milking station.
2 149 Hydraulic
pump - SW
internal error
Stop alarm Bug Should never occur. But if it does, restart
the milking station.
2 150 Hydraulic
pump - both
pressure
and temp
sensor
disabled
Stop alarm Should not be possible Enable one of the sensors in VmsConfig.2 150 Hydraulic
pump - both
pressure
and temp
sensor
disabled
Stop alarm Should not be possible Enable one of the sensors in VmsConfig.
2 151 Hydraulic
pump - too
long time in
manual
mode
without
doing any
manual work
Stop alarm See Alarm text Leave manual mode of the hydraulic pump
control.
2 151 Hydraulic
pump - too
long time in
manual
mode
without
doing any
manual work
Stop alarm See Alarm text Leave manual mode of the hydraulic pump
control.
2 203 Robot is
busy,
command
ignored
Status
message
This should never occur in
automatic mode unless the
operator has tried to carry out a
forbidden operation.
In manual mode, this error may
occur when an operation is tried
but the robot is already performing
some other operation.
Provided that the station is in automatic
mode and that no manual operation was
attempted when the error occurred, press
the "Save Logfiles" button on the touch
screen ("Miscellaneous Service" window).
Then notify service engineer.
Service engineer only: Call helpdesk.
2 203 Robot is
busy,
command
ignored
Status
message
This should never occur in
automatic mode unless the
operator has tried to carry out a
forbidden operation.
In manual mode, this error may
occur when an operation is tried
but the robot is already performing
some other operation.
Provided that the station is in automatic
mode and that no manual operation was
attempted when the error occurred, press
the "Save Logfiles" button on the touch
screen ("Miscellaneous Service" window).
Then notify service engineer.
Service engineer only: Call helpdesk.
2 204 AxisControll-
er not
connected
Stop alarm Internal error, shoul never occur.
The software for the axis control
has failed operating.
Restart the milking station. If the problem
persists, press the "Save Logfiles" button
on the touch screen as soon as possible
after the error has occurred ("Miscellaneous
Sevice" window). Notify service engineer.
Service engineer only: Notify Help desk in
Tumba.
2 204 AxisControll-
er not
connected
Stop alarm Internal error, shoul never occur.
The software for the axis control
has failed operating.
Restart the milking station. If the problem
persists, press the "Save Logfiles" button
on the touch screen as soon as possible
after the error has occurred ("Miscellaneous
Sevice" window). Notify service engineer.
Service engineer only: Notify Help desk in
Tumba.
2 205 AxisControll-
er is not
properly
configured
Stop alarm The parameters for the axis control
are invalid. Normally, this error
should never occur.
Possible causes:
- Parameters in the database are
invalid.
- The parameters in the database
were not successfully sent to the
arm (however, this is an internal
error and should never occur).
The robot must be re-calibrated.
Contact service engineer.
B) Service engineer only:
- Carry out an "Axis Controller calibration"
and a "Home calibration" (see VMS service
news no. 32).
- If the calibration does not solve the
problem, contact Help desk in Tumba.
2 205 AxisControll-
er is not
properly
configured
Stop alarm The parameters for the axis control
are invalid. Normally, this error
should never occur.
Possible causes:
- Parameters in the database are
invalid.
- The parameters in the database
were not successfully sent to the
arm (however, this is an internal
error and should never occur).
The robot must be re-calibrated.
Contact service engineer.
B) Service engineer only:
- Carry out an "Axis Controller calibration"
and a "Home calibration" (see VMS service
news no. 32).
- If the calibration does not solve the
problem, contact Help desk in Tumba.
171(198)