Troubleshooting
DeLaval voluntary milking system VMS
94897201.pdf2007-12-18
M m Alarm text Type Meaning ActionM m Alarm text Type Meaning Action
5 101 Endunit not
empty
Stop alarm The receiver (end unit) is not
empty.
This check is performed after a
cleaning or rinse of the system to
confirm that receiver does not
contain cleaning water.
Make sure there is no cleaning water in the
system before you start milking.
If the cleaning was stopped in an abnormal
way, carry out another cleaning or rinse to
be on the safe side.
5 101 Endunit not
empty
Stop alarm The receiver (end unit) is not
empty.
This check is performed after a
cleaning or rinse of the system to
confirm that receiver does not
contain cleaning water.
Make sure there is no cleaning water in the
system before you start milking.
If the cleaning was stopped in an abnormal
way, carry out another cleaning or rinse to
be on the safe side.
5 102 Tank valve
in wrong
position
Stop alarm The milk valve or the cleaning
valve (or both valves) at the tank is
in the wrong position.
Possible causes may be
insufficient air pressure, clogged
air valves or faulty sensors.
Technical explanation: the valves’
sensors, connected to Cx on board
A70 inside the milk-room-controller
box, do not give the expected
signals.
- Check the positions of the valves and
sensors.
5 102 Tank valve
in wrong
position
Stop alarm The milk valve or the cleaning
valve (or both valves) at the tank is
in the wrong position.
Possible causes may be
insufficient air pressure, clogged
air valves or faulty sensors.
Technical explanation: the valves’
sensors, connected to Cx on board
A70 inside the milk-room-controller
box, do not give the expected
signals.
- Check the positions of the valves and
sensors.
5 103 Cleaning not
completed
Stop alarm The milking station has been
stopped during a cleaning. When
the Milking Station is started again,
this message appears.
Check if a cleaning can be started and
completed.
Check the valves and the cleaning unit.
Make sure there is no water in system
before you start milking.
Note: If you do not know in which step the
cleaning was when it stopped, then run the
complete cleaning once again to prevent
bacteria or cleaning detergent from
contaminating the milk.
5 103 Cleaning not
completed
Stop alarm The milking station has been
stopped during a cleaning. When
the Milking Station is started again,
this message appears.
Check if a cleaning can be started and
completed.
Check the valves and the cleaning unit.
Make sure there is no water in system
before you start milking.
Note: If you do not know in which step the
cleaning was when it stopped, then run the
complete cleaning once again to prevent
bacteria or cleaning detergent from
contaminating the milk.
5 104 Cannot
accept milk
to tank
Deviation/St-
op alarm
Tank alarm. Milk cannot be
conveyed to the tank. The VMS
system will issue a Deviation as
soon as it receives the alarm from
the tank. If the tank still cannot
receive milk after 30 minutes have
passed, the VMS system will issue
a stop alarm. (The time limit can
be changed in the management
software > VMS Config).
Note: if the alarm involves some
problem with the cooling
functionality in addition to the fact
that the tank cannot receive milk,
the alarm is immediately issued as
a stop alarm.
Check which alarm the tank is sending,
then see the manuals for the cooling
equipment on what actions to take.
5 104 Cannot
accept milk
to tank
Deviation/St-
op alarm
Tank alarm. Milk cannot be
conveyed to the tank. The VMS
system will issue a Deviation as
soon as it receives the alarm from
the tank. If the tank still cannot
receive milk after 30 minutes have
passed, the VMS system will issue
a stop alarm. (The time limit can
be changed in the management
software > VMS Config).
Note: if the alarm involves some
problem with the cooling
functionality in addition to the fact
that the tank cannot receive milk,
the alarm is immediately issued as
a stop alarm.
Check which alarm the tank is sending,
then see the manuals for the cooling
equipment on what actions to take.
5 105 Cooling
alarm
User
notification
Tank alarm, cooling error. Check the cooling of the tank.5 105 Cooling
alarm
User
notification
Tank alarm, cooling error. Check the cooling of the tank.
5 106 Timeout
emptying
tank
Stop alarm The tank emptying has not been
finished wthin 30 minutes. A
possible reason is that the tank
cleaning has not been started.
The time limit can be changed in
the management software > VMS
Config.
Check why the tank emptying has not been
finished.
5 106 Timeout
emptying
tank
Stop alarm The tank emptying has not been
finished wthin 30 minutes. A
possible reason is that the tank
cleaning has not been started.
The time limit can be changed in
the management software > VMS
Config.
Check why the tank emptying has not been
finished.
5 107 Timeout
tankcleaning
Stop alarm The tank cleaning has not been
finished within 60 minuets.
The time limit can be changed in
the management software > VMS
Config.
Check why the tank cleaning has not been
finished.
5 107 Timeout
tankcleaning
Stop alarm The tank cleaning has not been
finished within 60 minuets.
The time limit can be changed in
the management software > VMS
Config.
Check why the tank cleaning has not been
finished.
181(198)