114 of 152 PSS5000/TEMA/803046/05
PSS 5000 – Technical Manual
9 W&M (Menu W)
To activate SECTEL
errors with local service
panel
This procedure describes how to activate the built-in checking device that
makes sure that the security telegram checking facility is operating correctly.
Note: It is assumed that the Idle menu is shown in the display.
1. Press to move to the LAM VERSION W.1 menu.
2. Press , , , , , to move to the CHECKING DEVICES W.7
menu.
3. Press , to move to the SEND ERR SECTEL W.7.2 menu.
4. Press , to move to the SEND ERR SECTEL menu.
5. Use the and buttons to toggle between ON and OFF.
When the SEC.TEL. ERROR value is
ON, this simulates that the security
telegram function has an error and the PSS 5000 must react accordingly.
6. Return the checking device setting to OFF before you leave the PSS 5000.
Failure to do this will result in the PSS 5000 not operating correctly.
9.7.3 LAM Code Error (Menu W.7.3)
To activate LAM code
errors with web service
pages
The procedure used here is the same procedure as is used to check all the de-
vices, see ‘To activate checking devices with web service pages’ on page 112.
To activate checking
LAM Code errors with
local service panel
This procedure describes how to activate the built-in checking device that
makes sure that the LAM Code checking facility is operating correctly.
Note: It is assumed that the Idle menu is shown in the display.
1. Press to move to the LAM VERSION W.1 menu.
2. Press , , , , , to move to the CHECKING DEVICES W.7
menu.