EasyManuals Logo

Doms PSS 5000 User Manual

Doms PSS 5000
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
PSS5000/TEMA/803046/05 53 of 152
PSS 5000 Technical Manual
5 Installation (Menu 2)
5.6 Software Upload (Menu 2.6)
Description of the
Software Upload menu
Software upload is done by uploading a file via FTP and/or by using the Web
interface (PSS program dependent).
An upload will clear the old program from the system, so normal operation is
interrupted during a program change. A program change automatically results
in a Master Reset of the system. Software uploads can be performed from a
remote location, but not before someone has set the system in a mode where it
is permitted to load software.
Setting the PSS 5000 to accept software uploads is enabled using either the
web service pages or the local service panel.
Software upload
methods
Several methods to upload software are available:
Important information
about BOOT and LAM
software
For the PSS 5000 system, two series of program combinations exist (BOOT,
LAM and Application). Combinations other than those shown in the table be-
low are incompatible. The following conditions must be fulfilled:
Read the Software Release Document for the Application Program to see
which BOOT and LAM versions are required.
If you are not sure which software versions are currently installed in the PSS
5000, see ‘4.1 Program Versions (Menu 1.1)’ on page 27.
If the current versions are not correct, change the software in the following or-
der: BOOT, LAM and/or APPLICATION. Use either of the following proce-
dures to do this:
‘To upload software with the web service menus’ on page 54, or
‘To upload software using FTP’ on page 56
Interface Description
Old web service menus Software upload followed by an FTP upload program
session.
New web service menus Software upload followed by an FTP upload program
session.
Software upload followed by a Web applet based up-
load program session.
Local service panel Software upload followed by an FTP upload program
session.
FTP Software upload by uploading file ok2load.txt followed
by an FTP program upload session.
Application Version Condition
All versions before 1.00 Must use:
BOOT program from the 400-02 series
LAM version lower than 1.00
Version 1.00 or higher Must use:
BOOT program from the 499-03 series
LAM version 1.00 or higher

Table of Contents

Other manuals for Doms PSS 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Doms PSS 5000 and is the answer not in the manual?

Doms PSS 5000 Specifications

General IconGeneral
BrandDoms
ModelPSS 5000
CategoryController
LanguageEnglish